Fire Protection Consulting Services Research Proposal

Pages: 4 (1121 words)  ·  Bibliography Sources: 3  ·  File: .docx  ·  Level: College Senior  ·  Topic: Business

Fire Protection Consulting Services

Business activity as it applies to fire issues

Phoenix Fire Protection, LLC designs fire detection, prevention, and extinguishment system for different types of businesses. Its main purpose is to identify the needs of a business in terms of fire protection systems and to implement the proposed solutions into an overarching framework that will cover both the physical instruments (fire extinguishers, fire alarms, sprinkler systems etc.) and the training components (how to use all the instruments).

The purpose of this business plan is to design such a system for Ajax Metal Fabricators, a company specialized in the production and fabrication of different types of metals. There are some particularities of this type of business, notably fires that are potentially more dangerous and destructive, because of the nature of the metals, and that need to be addressed in a particular manner. This particularized approach will include a larger number of fire extinguishers, more attention to training, as well as to the maintenance processes.

Fire alarm design and installation

There are three types of fire alarm systems: manual systems (M), systems designed to protect life (L) and systems designed to protect buildings (P)

. Given the size and complexity of the activity at Ajax Metal Fabricators, this business plan will deal only with the latter two. In terms of the P. fire alarms, both P1 and P2 will be required, with the P2 fire alarms being installed in the areas where the metal is actually fabricated and where there is a higher risk of fire.

Download full
paper NOW!  ⬇️
In terms of the L. category, L3 fire alarms will be given preference, as a more overarching type of fire alarm that can give early warning to most of the people in the building. L2 fire alarms can be added to the halls and rooms where the metal is fabricated and where there is a larger chance of fire.

Sprinkler system design and installation

TOPIC: Research Proposal on Fire Protection Consulting Services Assignment

NFPA 13 contains the necessary regulatory information for the design and installation of sprinkler systems. Automatic fire sprinklers will be necessary and should be set to go off at a temperature of 149 degrees Fahrenheit. The reason why this higher temperature can be accepted is that the metal fabrication process implies the use of extreme heat and it may be the norm for such high levels to be reached at ceiling level when performing day-to-day activities in the manufacturing rooms.

The sprinkler system should cover the rooms where the metals are being fabricated. The sprinkler system should also cover the area immediately close to these rooms, so as to be able to contain the fire and prevent it from potentially extending to other parts of the building. In these rooms, open orifice sprinklers can be used instead.

Portable fire extinguisher requirements and placement

In order to define the portable fire extinguisher requirements and placement, one first needs to define the type of class the fire is part of. In this particular case, since the client is Ajax Metal Fabricator, one can expect that the fire is a Class D fire in particular. According to the NFPA 10, this class refers to "fires in combustible metals, such as magnesium, titanium, zirconium, sodium, lithium, and potassium"

The selection of the fire extinguisher is thus determined by the classification of the fire, which points to the type of hazard that might be expected.… [END OF PREVIEW] . . . READ MORE

Two Ordering Options:

?
  1. To download this paper immediately, it takes only 2 minutes to subscribe.  You can individually download any of our 2,000,000+ private & exclusive papers, 24/7!  You'll also receive a permanent, 10% discount on custom writing.  (After you pay and log-in, the "Download Full Paper" link will instantly download any paper(s) that you wish!)
  2. One of our highly experienced experts will write a brand new, 100% unique paper matching the exact specifications and topic that you provide!  You'll be the only person on the planet to receive the one-of-a-kind paper that we write for you!  Use code "Save10" to save 10% on your 1st order!
1.  Download full paper (4 pages)⬇️

Download the perfectly formatted MS Word file!

- or -

2.  Write a NEW paper for me!✍🏻

We'll follow your exact instructions!
Chat with the writer 24/7.

Private Security Contractors Thesis


Clinton Cole v. Burns International Security Services Case Report Term Paper


Enron's Misleading Accounting & Fraud Tactics Thesis


Environmental Policy Specifically Eis Statement Thesis


Computer Hacker Term Paper


View 200+ other related papers  >>

How to Cite "Fire Protection Consulting Services" Research Proposal in a Bibliography:

APA Style

Fire Protection Consulting Services.  (2011, August 17).  Retrieved January 16, 2022, from https://www.essaytown.com/subjects/paper/fire-protection-consulting-services/487902

MLA Format

"Fire Protection Consulting Services."  17 August 2011.  Web.  16 January 2022. <https://www.essaytown.com/subjects/paper/fire-protection-consulting-services/487902>.

Chicago Style

"Fire Protection Consulting Services."  Essaytown.com.  August 17, 2011.  Accessed January 16, 2022.
https://www.essaytown.com/subjects/paper/fire-protection-consulting-services/487902.